دانلود مقاله ISI انگلیسی شماره 26907
ترجمه فارسی عنوان مقاله

تجزیه و تحلیل حساسیت از جرثقیل های موازی با استفاده از روش خطی فاصله

عنوان انگلیسی
Sensitivity analysis of parallel manipulators using an interval linearization method
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
26907 2014 12 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Mechanism and Machine Theory, Volume 71, January 2014, Pages 93–114

ترجمه کلمات کلیدی
منبلترس موازی - تجزیه و تحلیل حساسیت - روش خطی فاصله -
کلمات کلیدی انگلیسی
Parallel manipulators, Sensitivity analysis, Interval linearization method,
پیش نمایش مقاله
پیش نمایش مقاله   تجزیه و تحلیل حساسیت از جرثقیل های موازی با استفاده از روش خطی فاصله

چکیده انگلیسی

The subject of this paper is about an interval linearization method for the sensitivity analysis of manipulators to variations in their geometric parameters. First, the proposed method is presented. Then, three manipulators are used as illustrative examples: The five-bar mechanism, the 3-RRR planar parallel manipulator and the Orthoglide. The benefits and restrictions of the proposed method are also discussed and appropriate indices are derived to show the efficiency of the method. The obtained results are also compared with the results obtained with frequently used methods. The proposed method is simple to implement and provides verified results in low computational time and thus can be applied to complex robots such as the Orthoglide. In particular, the standard linearization method computes unreliable results near singularities, whereas the proposed interval linearization method automatically detects such situations.

مقدمه انگلیسی

Many robotic applications require high precision. This precision cannot be achieved unless all sources of errors have been identified and integrated in dedicated computational methods. Amongst the well known sources of errors we find manufacturing errors, joint clearances, and backlashes in the actuators. The sensitivity analysis of a manipulator aims at knowing the influence of variations in its geometric parameters and/or actuators on its performance. This information is useful for the evaluation of the pose error of the end-effector and for the tolerance synthesis. The three main methods used for the sensitivity analysis to variations in geometric parameters and joint clearances of serial and parallel robots are: (i) the probabilistic methods [1]; (ii) the linearization methods [2]; and (iii) the interval analysis methods [3]. As indicated in [4], science was based in the last centuries on deterministic ideas, which consist in believing that since each phenomenon is due to a determined cause, the behavior can be predicted. However, since it is usually impossible to gather enough information for the behavior to be predictable, probabilistic theories were born. The probabilistic approaches are well known in several engineering fields such as nonlinear dynamics and robotics. Recently, in [5], a probabilistic approach was used in the field of Human–Robot communication. In [1], the sensitivity analysis for a two-link planar manipulator and the Stanford arm was conducted according to a probabilistic method. The authors pointed out that the probabilistic model of the kinematics and dynamics of these robots will be reliable if a sufficient number of experiments are conducted, which means that the results will not be verified. The probabilistic approaches present the advantage of having a competitive computational time while being simple and general. However, they do not provide any verified result. Other methods for sensitivity analysis do exist such as the linearization method, which consists in analyzing the sensitivity of the linearized system. The linearization method is a numerical method that does not provide verified results [6], [7] and [8]. In [2], [9], [10] and [11], the authors worked on the sensitivity analysis of planar parallel manipulators using the linearization method. This method is suitable for small uncertainties and as long as the robot is not close to singular configurations. The computed sensitivity may be lower than the real one. For instance, the linearization method was used to analyze the sensitivity of the Orthoglide to variations in its geometric parameters [12]. The sensitivity of parallel manipulators to joint clearances is also an important issue. The great impact that joint clearances can have on the end-effector pose of the manipulator was highlighted in [8]. Furthermore, as mentioned in [13], errors due to joint clearances cannot be compensated by calibration contrary to manufacturing and assembling errors. To analyze the effect of joint clearances, a complete mathematical model of the joint should be defined. For instance, a joint can be modeled as a journal bearing [14]. The same model was used in [15] in order to compute the effect of joint clearances. A general approach was proposed in [16] but turns out to be time consuming. A general error-prediction model has been recently developed in [17]. Accordingly, two optimization problems were formulated in order to find the maximum positioning and orientation errors of the end-effector of the manipulator due to joint clearances. Again, the previous research works without minimizing their importance are based on algebraic methods that do not provide verified results. On the contrary, interval analysis based approaches provide verified results while being simpler than their counterparts. In [18] the authors used a Newton–Raphson based interval analysis method combined with a bisection algorithm in order to analyze the sensitivity of simple mechanisms to joint clearances. However, their approach is complicated and time consuming because it requires a bisection algorithm. Moreover, the method has not been applied to complex mechanisms, and the authors did not give enough information about the behavior of their algorithm close to singular configurations. The standard linearization method turns out to be simple to use and provides good results as long as the variations in the parameters are small enough. Therefore, the standard linearization method may provide bad results. In this paper, we propose an interval linearization method that combines the simplicity of the standard linearization method and the verification of the results. Moreover, the proposed method is simpler than the approach described in [18] and allows us to analyze the sensitivity of complex robots to geometric errors and joint clearances. The paper is organized as follows. Section 2 introduces the proposed interval linearization method for the sensitivity analysis of parallel manipulators. An efficiency index of the method is also developed with regard to the amount of uncertainties. Section 3 deals with the sensitivity analysis of the five-bar mechanism and makes a comparison between the results obtained with the proposed method and the ones obtained with a standard linearization method. Section 4 deals with the sensitivity analysis of the 3-RRR planar parallel manipulator with the proposed interval linearization method. Section 5 deals with the sensitivity analysis of the Orthoglide, a three degree of freedom translational parallel manipulator, using the proposed interval linearization method and two geometric models of the manipulator.

نتیجه گیری انگلیسی

The interval linearization method proposed in this paper provides verified results for the sensitivity analysis of serial and parallel manipulators since it is based on a rigorous linearity that takes nonlinearities into consideration. This fact represents a major advantage in comparison with probabilistic and standard linearization methods. The method turns out to give accurate results even when the manipulator under study is close to a singular configuration. As a matter of fact, as long as the algorithm converges, it will provide verified and relevant results. It means that we provided an auto validation algorithm: If it provides results, they will be verified even close to singular configurations. It is a major advantage in comparison with the standard linearization method where results are provided even too close to singular configurations, but are not reliable. It has also proved to be general since it works for simple mechanisms such as the five-bar mechanism, and complex ones such as the Orthoglide. The method proposed in this paper was implemented using the Interval Laboratory Intlab[20] that works under Matlab. Implemented on a 1.86 GHz Intel Pentium Dual-core CPU, and a 3 GHz memory, 30 s were required to draw the isocontours for the five-bar mechanism, whereas up to 1 min was required to analyze the sensitivity of the Orthoglide. However, when the full mathematical model of the Orthoglide was used, the computational time had been higher, since the corresponding model is very complex and implements hundreds of trigonometric functions in each of the six equations. We can say that our method is faster than the algorithm presented in [18] since no bisection is needed. As a conclusion, the proposed method for the sensitivity analysis of serial and parallel manipulators provides verified results and the computation time is acceptable. Later on, the method will be used to compute the maximum pose errors of serial and parallel manipulators due to joint clearances.