دانلود مقاله ISI انگلیسی شماره 28582
ترجمه فارسی عنوان مقاله

رفتار سازه از ستون های کانال فولاد کوتاه دیواره نازک سرد در دمای بالا. قسمت 1: تجربیات

عنوان انگلیسی
Structural behaviour of cold-formed thin-walled short steel channel columns at elevated temperatures. Part 1: experiments
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
28582 2003 28 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Thin-Walled Structures, Volume 41, Issue 6, June 2003, Pages 543–570

ترجمه کلمات کلیدی
ستون های کوتاه دیواره - تست دمای بالا - مقاومت در برابر آتش - بخش سوراخ شده - فولاد سرد - تست استحکام - کمانش محلی
کلمات کلیدی انگلیسی
Thin-walled columns, Elevated temperature tests, Fire resistance, Perforated section, Cold-formed steel, Strength tests, Local buckling
پیش نمایش مقاله
پیش نمایش مقاله  رفتار سازه از ستون های کانال فولاد کوتاه دیواره نازک سرد در دمای بالا. قسمت 1: تجربیات

چکیده انگلیسی

Cold-formed thin-walled steel structures are increasingly being used as primary load bearing members. However, there is a lack of study of their performance in fire. This paper presents a detailed description of an experimental study of the axial strength of cold-formed thin-walled channel sections under ambient and uniform high temperatures. The objectives of this study are two-fold: to gain an insight into the physical behaviour and failure modes of this type of structure and to provide some experimental results for detailed numerical studies. A total of 52 strength tests were carried out on short cold-formed lipped channels with and without service holes and unlipped channels at ambient and various elevated temperatures. From these experimental studies, it has been observed that the failure mode of two nominally identical columns can be different even though the failure loads are close. Depending on the thickness of a channel and the location of the service hole, perforation can have an important effect on the strength of the channel, irrespective of the temperature. The companion paper will describe the results of design calculations and numerical studies.

مقدمه انگلیسی

Cold-formed thin-walled steel members provide a high strength to weight ratio and are also easy to construct when compared to thicker hot-rolled steel members. Because of these, cold-formed thin-walled steel sections as load-bearing structural components are widely used in domestic and industry buildings and in almost any imaginable location since it was first applied in building construction in about 1850 in USA. Its applications and our understanding of its behaviour have been further expanded in various fields by leaps and bounds since the first specification for cold-formed steel design was issued by the American Iron and Steel Institute (AISI) in 1946. However, one of the main disadvantages of cold-formed thin-walled steel as a structural material is its low fire resistance because of a combination of the high thermal conductivity of steel and the high section factor of the structural member, both leading to rapid steel temperature rises in fire. Nevertheless, despite increasing use, studies of the fire performance of cold-formed thin-wall steel members are rare and available information in the literature is scarce [1], [2], [3], [4], [5], [6], [7], [8], [12], [13], [14], [16], [19] and [20]. There are a number of important differences between the fire behaviour of cold-formed thin-walled steel members and that of hot-rolled ones. Firstly, the mechanical properties at elevated temperatures are different. Cold-forming steel has a strengthening effect at ambient temperature, but this strengthening effect is reduced at elevated temperatures. Secondly, due to the nature of fire protection to thin-walled steel members and the fact that thin-walled members are usually exposed to fire attack on one side, temperature distributions in thin-walled steel members under fire attack are highly non-uniform and different from those in hot-rolled members. Thirdly, thin-walled steel members usually have more complex buckling behaviour, involving local, distortional, global buckling and their interactions. In addition, for easy installation of electrical wires and plumbing systems, pre-punched service holes are often introduced in the web of a thin-walled steel member. Although the effect of a web opening in a column at ambient temperature has been investigated by many researchers [9], [10], [11], [15], [17], [18] and [21], the effect of perforation under high temperatures is not clear and there are very few studies of the fire performance of cold-formed thin-walled steel columns with holes. As a result, no design method is available for this type of construction. At present, fire resistant design of cold-formed thin-walled steel structures is often based on the results of manufacturers’ standard fire tests. Not only is this expensive, but it also limits flexibility of the designer. In order to develop rational and general fire engineering design methods for cold-formed thin-walled steel structures, a study of the behaviour of cold-formed thin-walled steel structures in fire has been recently started in the Structures and Fire Research Group at the University of Manchester with financial support from the EPSRC. This paper reports the results of a number of tests on cold-formed thin-walled steel short columns with and without holes under ambient and uniform high temperature conditions. The objectives of these experiments are to study the failure modes of short thin-walled columns at elevated temperatures and to provide data for checking and validating design and numerical prediction methods for local and distortional buckling. The companion paper will describe the results of design calculations and numerical studies.

نتیجه گیری انگلیسی

This paper has presented the results of an experimental investigation into the strength of cold-formed thin-walled steel short columns under uniform high temperatures. A total of 52 short column tests were conducted to assess their local and distortional buckling behaviour. From the experimental results, the following conclusions may be drawn: • Depending on initial imperfections, the failure mode of nominally identical columns can be different. This applies to both ambient and elevated temperature tests. • Despite the difference in failure modes, the failure loads of nominally identical columns were very close. • The service hole in lipped channels did not seem to affect the overall column axial stiffness. However, it changes the column buckling mode and can have a significant effect on the column load carrying capacity. Depending on the reduction in the yield strength relative to that in the elastic modulus of steel at elevated temperatures, the effect of holes can become much higher than that at ambient temperature.