دانلود مقاله ISI انگلیسی شماره 61629
ترجمه فارسی عنوان مقاله

مدل طراحی برای تحلیل روابط میان گازهای گلخانه ای CO2، هزینه و پارامترهای ساختاری در ساخت و ساز ساختمان سبز با ستون کامپوزیت

عنوان انگلیسی
Design model for analysis of relationships among CO2 emissions, cost, and structural parameters in green building construction with composite columns
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
61629 2016 15 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Energy and Buildings, Volume 118, 15 April 2016, Pages 301–315

ترجمه کلمات کلیدی
مدل طراحی پایدار؛ ساخت و ساز ساختمان سازی سبز؛ گاز گلخانه ای؛ مدل طراحی بهینه
کلمات کلیدی انگلیسی
Embodied CO2; Sustainable design model; Green building construction; Greenhouse gas; Optimal design model
پیش نمایش مقاله
پیش نمایش مقاله  مدل طراحی برای تحلیل روابط میان گازهای گلخانه ای CO2، هزینه و پارامترهای ساختاری در ساخت و ساز ساختمان سبز با ستون کامپوزیت

چکیده انگلیسی

Although a concrete-filled steel tube (CFT) column, which is one of the composite columns frequently used in building construction because of its structural performance, economic feasibility, and good space utilization, has a high potential to reduce CO2 emissions because of combining two heterogeneous materials, the relationship among CO2 emissions, cost, and structural parameters in green construction of buildings with CFT columns was not yet carried out. In this study, an optimum design model was proposed to analyze the relationship. Based on the analysis, it was founded that CFT with circular sections were more effective than square type in terms of CO2 emissions and cost by 57.03% and 11.18%, respectively, while square type was advantageous in aspect of space utilization than the circular section by 9.73%. Also, with the consideration of various strengths of materials, CO2 emissions, cost, and space utilization for the columns can be reduced by 24.38%, 29.66%, and 21.08%, respectively. In addition, the proposed model was applied to construction of a 35-story real building. From the analysis of optimum designs for the building, the circular section was more advantageous than square section regarding the CO2 emission and material cost by 2.47% and 8.57%, respectively, while square section occupied smaller space than circular section by 17.95%. It is concluded that CO2 emission, cost, and space utilization of the column in the real building can be reduced by 21.05%, 14.97%, and 20.18%, respectively, with the optimum section type and material strength.