دانلود مقاله ISI انگلیسی شماره 157016
ترجمه فارسی عنوان مقاله

توسعه مفهومی سیستم فتوولتائیک ساختمان یکپارچه؟ سیستم تشعشعی خنک کننده و تجزیه و تحلیل عملکرد اولیه در شرق چین

عنوان انگلیسی
Conceptual development of a building-integrated photovoltaic–radiative cooling system and preliminary performance analysis in Eastern China
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
157016 2017 9 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Applied Energy, Volume 205, 1 November 2017, Pages 626-634

ترجمه کلمات کلیدی
فتوولتائیک، خنک کننده شعاعی، ساختمان، انتخابی طیفی،
کلمات کلیدی انگلیسی
Photovoltaic; Radiative cooling; Building; Spectral selectivity;
پیش نمایش مقاله
پیش نمایش مقاله  توسعه مفهومی سیستم فتوولتائیک ساختمان یکپارچه؟ سیستم تشعشعی خنک کننده و تجزیه و تحلیل عملکرد اولیه در شرق چین

چکیده انگلیسی

Building-integrated photovoltaic/thermal (BIPV/T) technology has been receiving considerable research attention because of its ability to generate electricity and thermal energy simultaneously. However, space cooling is crucial for buildings in hot regions where space heating is of little use. This study proposed a building-integrated photovoltaic–radiative cooling system (BIPV–RC) that can generate electricity via photovoltaic (PV) conversion during daytime and generate cooling energy via radiative cooling (RC) during nighttime to satisfy the demand in such areas. The selective plate, which is the main component of the BIPV–RC system, exhibits high spectral absorptivity (emissivity) in the PV conversion band of crystalline silicon solar cells and in the atmospheric window band (i.e., 0.3–1.1 μm and 8–13  μm), as well as low spectral absorptivity (emissivity) in other bands. A quasi-steady-state mathematical model was built, and its performance under realistic ambient conditions was analyzed. The electrical efficiencies of the BIPV–RC and conventional BIPV systems were then compared under different solar radiations. Comparison results show that the annual electricity production and cooling energy gain of the BIPV–RC system in Hefei reached 156.74 kW h m−2 (equivalent to 564.26 MJ m−2) and 579.91 MJ m−2, respectively. The total electricity production and cooling energy gain of this system are 96.96% higher than those of the BIPV system. Parametric studies show that the precipitable water vapor amount has remarkable effects on the nocturnal RC performance of the BIPV–RC system. A small precipitable water vapor amount corresponds to a high nocturnal RC power, thereby implying that a dry climate condition benefits the nocturnal RC of this system.