دانلود مقاله ISI انگلیسی شماره 57024
ترجمه فارسی عنوان مقاله

اعتبار و قابلیت اطمینان از کفی های اندازه گیری فشار برای ارزیابی نیروی واکنش زمین عمودی در شرایط محیطی

عنوان انگلیسی
Validity and reliability of pressure-measurement insoles for vertical ground reaction force assessment in field situations
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
57024 2016 8 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Applied Ergonomics, Volume 53, Part A, March 2016, Pages 44–51

چکیده انگلیسی

This study aimed to test the validity and reliability of pressure-measurement insoles (medilogic® insoles) when measuring vertical ground reaction forces in field situations. Various weights were applied to and removed from the insoles in static mechanical tests. The force values measured simultaneously by the insoles and force plates were compared for 15 subjects simulating work activities. Reliability testing during the static mechanical tests yielded an average interclass correlation coefficient of 0.998. Static loads led to a creeping pattern of the output force signal. An individual load response could be observed for each insole. The average root mean square error between the insoles and force plates ranged from 6.6% to 17.7% in standing, walking, lifting and catching trials and was 142.3% in kneeling trials. The results show that the use of insoles may be an acceptable method for measuring vertical ground reaction forces in field studies, except for kneeling positions.