دانلود مقاله ISI انگلیسی شماره 147666
ترجمه فارسی عنوان مقاله

تست های لوله های فولادی مقاوم در برابر سرما که در معرض ریزش مو هستند

عنوان انگلیسی
Tests of cold-formed high strength steel tubular sections undergoing web crippling
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
147666 2017 13 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Engineering Structures, Volume 141, 15 June 2017, Pages 571-583

ترجمه کلمات کلیدی
فولاد سازی سرد تحقیقات تجربی، فولاد با مقاومت بالا سازه های فلزی، بخش لوله وب گمشده،
کلمات کلیدی انگلیسی
Cold-formed steel; Experimental investigation; High strength steel; Steel structures; Tubular section; Web crippling;
پیش نمایش مقاله
پیش نمایش مقاله  تست های لوله های فولادی مقاوم در برابر سرما که در معرض ریزش مو هستند

چکیده انگلیسی

This paper presents an experimental investigation of cold-formed high strength steel tubular sections undergoing web crippling. The tests were conducted on square and rectangular hollow sections of high strength steel with nominal 0.2% proof stresses of 700 and 900 MPa. The measured web slenderness values of the tubular sections ranged from 8.3 to 35.8. Tensile and compression coupon tests were conducted to obtain the material properties of the test specimens. The web crippling tests were conducted under the four loading conditions as specified in the North American Specification and Australian/New Zealand Standard for cold-formed steel structures, namely, the End-One-Flange, Interior-One-Flange, End-Two-Flange and Interior-Two-Flange loading conditions. It should be noted that the web crippling design provisions in these two specifications were mainly developed based on sections with web slenderness value greater than 40 and 0.2% proof stress less than 500 MPa. The test strengths obtained from this study were compared with the nominal strengths calculated from the North American Specification, Australian/New Zealand Standard and European Code for cold-formed steel structures. Furthermore, the test strengths were also compared with the nominal strengths calculated from the Australian Standard AS4100. Reliability analysis was performed to assess the reliability of the design provisions in the aforementioned specifications. Generally, it is shown that the nominal strengths predicted by the codified web crippling design provisions are either unconservative or very conservative. Hence, the existing codified design provisions are not appropriate for the cold-formed high strength steel square and rectangular hollow sections undergoing web crippling.