دانلود مقاله ISI انگلیسی شماره 122722
ترجمه فارسی عنوان مقاله

بررسی تجربی رفتار هیسترتیک از پرتو کامپوزیت فولادی بتن ساده شده

عنوان انگلیسی
Experimental investigation on hysteretic behavior of simply supported steel-concrete composite beam
کد مقاله سال انتشار تعداد صفحات مقاله انگلیسی
122722 2018 13 صفحه PDF
منبع

Publisher : Elsevier - Science Direct (الزویر - ساینس دایرکت)

Journal : Journal of Constructional Steel Research, Volume 144, May 2018, Pages 153-165

ترجمه کلمات کلیدی
تیرهای کامپوزیت فولادی، آزمون نیمه استاتیک، عملکرد هیسترتیک، درجه اتصال برشی،
کلمات کلیدی انگلیسی
Steel-concrete composite beams; Quasi static test; Hysteretic performance; Degree of shear connection;
پیش نمایش مقاله
پیش نمایش مقاله  بررسی تجربی رفتار هیسترتیک از پرتو کامپوزیت فولادی بتن ساده شده

چکیده انگلیسی

This study aimed to investigate the seismic behavior of simply supported steel–concrete composite I beam and box beam through a quasi-static experimental study. A total of 22 composite beams included in the experiments, and parameters including shear connection degree, transverse reinforcement ratio, longitudinal reinforcement ratio, section type, diameter of stud, and web thickness were investigated. Based on the test, hysteretic response, skeleton curves, failure mode, stiffness degradation, ductility, and energy dissipation were discussed. Results show the following: (1) Composite beams have favorable seismic performance, the displacement ductility ratio ranged from 2.5 to 8.75, whereas the maximum equivalent viscous damping ratio ranged from 0.219 to 0.470. (2) The higher the degree of shear connection, longitudinal reinforcement, and transverse reinforcement, the plumper the hysteretic curve and the greater the bearing and energy dissipation capacity. The ductility of composite beam increased as the longitudinal reinforcement ratio increased. The stiffness degradation and residual deformation were less effected by other parameters. (3) Findings suggest that the transverse reinforcement ratio ranged from 0.4% to 0.8%, the positive shear connection degree should be greater than 1, and the spacing of stud in the negative moment region should not be larger than that in the positive moment region. To ensure welding quality and convenient construction, a large diameter of stud should be applied in practical engineering. Moreover, when the girder is welded by a thin web, transverse diaphragm plate and vertical reinforced rib should be added in the steel girder if these areas are heavily loaded.